PTFE septa for reactive samples

Position:
Home » News » HPLC Septa Cap » PTFE septa for reactive samples

Sample handling solutions - Fisher Sci

PTFE Septa * -200 +250 -328 +482 Polyethylene (PE) * -50 +80 -58 +176 Polypropylene (PP) * 0 +121 32 +250 Butyl/Chlorobutyl/Bromobutyl Stopper or Septa -20 +125 -4 +257 Gray PTFE/Red Rubber -40 +120 -40 +248 PTFE/White Silicone PurePack Septa -60 +200 -76 +392 Gray PTFE/Molded Black Butyl (Pharmafix) Septa -20 +125 -4 +257

Silicone Septa at Thomas Scientific

Chemglass. Replacement septa for use with MW-102 open-top screw caps on Minum-Ware® glassware components. Septa are made of silicone rubber with one side having a RED PTFE face, while the opposite side has an ultrathin covering of polypropylene to prevent needle coring when penetrating septa. Compare this item.

Sample Vials and Accessories - Waters Corporation

PTFE chemical resistance until punctured, then the septum will have the chemical compatibility of silicone Working temperature range from -40 ˚C to 200 ˚C Pre-slit PTFE/Silicone Provides adequate venting to prevent vacuum formation in sample vial, delivering excellent sample-draw reproducibility Eliminates coring from bottom draw needles

Vials/Caps/Septa Manufacturer Syringe Filter Manufacturer Lab

white PTFE/red Silicone septa, 11mm crimp-top aluminum cap,5.5mm centre hole pre-slit white PTFE/red Silicone septa, 11mm crimp-top aluminum cap,5.5mm centre hole Non-slip Nature PTFE/White Silicone septa,11 mm crimp -top aluminum cap, 5.5 mm centre hole 100pcs/pk 100pcs/pk Model No. Description IPA150 IPB250 IA250 IA250 IPB250 IB300 IB300 V18A

Aijiren Certified Vials, Caps and Septa - Postnova

Dislodged or misaligned septa • Sample loss Silver aluminum, thin PTFE septa 100/pk 5182-0871 Magnetic crimp caps for CTC Autosampler 100/pk

Septa selection guide

the solvent. PTFE/Silicone septa are ideal for use in most HPLC and GC applications where resealability and purity are critical. Pre-slit PTFE/silicone septa Pre-slit septa are offered in many of the same formulations as for non-slit PTFE/silicone septa and shares most of the physical and chemical characteristics.

Sample handling solutions - Crawford Scientific

PTFE/Silicone Septa: (T/S) PTFE/Silicone is the most versatile septum material offered in various formulations to address specific applications requirements . Extractables from PTFE/Silicone septa are generally at lower levels compared to other resealable materials . PTFE/Silicone septa are formulated for different hardness (durometer)

Septa at Thomas Scientific

Vial septa are available in a variety of materials. Septa, tan PTFE/silicone (diam. x thickness 8 mm x 1.5 mm) are sized to fit screw top vials. They are suitable for use with most organics (until pierced) and are not recommended for use with chlorosilanes. Compare this item.

CHAPTER FOUR TABLE OF CONTENTS Section Page 4-1 RECOMMENDED

Dec 11, 2018 · burrs around the caps that might prevent the vial from sealing, and septa should be lined with a polytetrafluoroethylene (PTFE) layer of sufficient thickness to limit diffusion of VOCs out of the vials during storage. PTFE thicknesses of 0.13 to 0.25 mm have been shown to be effective. See reference# 18 in Sec. 4.6 below and Sec.

Accessory Product Data Sheet - .NET Framework

Both types of silicone and butyl rubber septa have a PTFE barrier layer which faces the sample, which reduces the contact between the sample and the silicone and butyl rubber. Before the PTFE layer is punctured, the chemical compatibility properties of the PTFE will

Bottle Septa | Fisher Scientific

Bottle Septa. Septa for bottles provide an airtight seal for bottles that prevents environmental contaminants but allows for the removal of the bottle’s contents by piercing with sharp needles. Septa bottle caps are generally available for open-top and screw caps and allow for aseptic syringe dispensing, as well as the addition of materials.

TurboMatrix Headspace Samplers - PerkinElmer

PTFE-Coated Silicone, Pre-assembled 1000 B4000022 20 mm Gray Butyl/PTFE Pre-assembled Cap/Septa/Spring 1000 N9306264 20 mm Gray Butyl/PTFE Pre-assembled Cap/Septa/Spring 100 N9306265 Clear 20 mL Headspace with Write-On Patch and Fill Lines Gray PTFE/Butyl Kit, Unassembled Cap/Septa/Spring 100 N9306266

SureSTART™ Specification Certified Screw Vial and Cap Kits

Select Level 3 products for ultimate performance and sensitivity from your methods, while maintaining the highest levels of sample security and integrity. Choose from a variety of kits containing short thread screw vials in glass or TPX and polypropylene caps with silicone/PTFE septa designed to reduce autosampler needle issues.

How to Choose a Septa Pre-slit or Not? - Hplc Vials

Jul 31, 2020 · Needle Gauge: A bigger needle gauge can need more force to get through non-pre-slit septa, which could cause damage to the septa or sample contamination. A pre-slit septum might be the best choice in this situation. Injection Frequency: A pre-slit septa may be more appropriate for applications requiring repeated injections since it can lessen

High Temperature Septa at Thomas Scientific

Hamilton. High Temperature Septa is made of preconditioned PTFE/silicone rubber and is 3.175 mm (0.125 in.) thick. The average life of these septa is up to 100 injections with a 26s gauge needle. The maximum operating temperature is 212° C. Preconditioned PTFE/silicone rubber septa, 3.175 mm. Compare this item.