PTFE/silicone septa for chromatography tools

Position:
Home » News » HPLC Septa Cap » PTFE/silicone septa for chromatography tools

6-20mL 20mm Crimp-Top Headspace ND20

Features. 1).Crimp caps provide a consistently secure seal. 2).Beveled top for maximum secure seal. 3).Choice of a pressure safety release cap at 45 psi. 4).10/20mL Clear /Amber Precision Crimp Headspace Vial, Flat/Round Bottom, 22.5*46mm. 5).PTFE/Silicone Septa Φ20*3mm Temperature Resistant -60-200 with 9mm thread.

TurboMatrix Consumables Guide (009709C 01) - PerkinElmer

PTFE/Butyl (Pharma Fix Septa) Aluminum Cap N9306224 PTFE/Red Rubber (red) Aluminum Cap, Star Spring and Septa N9304147 N9302978 PTFE/Silicone (white) Aluminum Cap, Star Spring and Septa N9304146 B4000022 PTFE/Silicone (white) Low Bleed Aluminum, Skived Pressure Relief N9302975 PTFE/Silicone (white) Low Bleed Aluminum, Skived (non-Pressure

Headspace Vials & Headspace Caps - Aijiren

Aijiren's headspace vial caps are engineered to prevent sample contamination while providing consistent, secure seals. Headspace vial caps are available in a variety of materials including aluminum, bimetal, and steel; headspace vial cap septa are available in PTFE/silicone, molded PTFE/butyl, and high-temperature varieties.

An Aijiren Septum is Not Just a Septum

selecting septa. PTFE/red rubber septa are not recommended for multiple injections or for samples that need to be stored for further analysis. When applications require a longer time between injections or any type of standard additions, PTFE/silicone septa are always best. What force is required to penetrate the septum?

Septum Selection Guide Rev 2 - Fisher Sci

PTFE/Silicone septa are the preferred product for use in most HPLC and GC applications where resealability and high purity are critical. PTFE/Silicone septa are offered in a standard formulation as well as a soft durometer formulation recommended for applications where ease of needle penetration is important PTFE/Silicone/PTFE Septa: (T/S/T)

Septa Selection Tool | Thermo Fisher Scientific - CA

Silicone rubber septa. High quality, silicone rubber laminated to PTFE. Use when excellent resealing qualities are a must. Septum resists coring and is recommended when multiple injections are required. Preferred septa for use in liquid chromatography applications.

Accessory Product Data Sheet - .NET Framework

Accessory Product Data Sheet Septum Selection Guide 411 Madrid Avenue Torrance, CA 90501 Tel: 310-212-0555 Fax: 310-328-7768 www.phenomenex.com

Septa Selection for Autosampler Vials - LinkedIn

Sep 8, 2022 · PTFE/silicone: A very pure soft silicone laminated to PTFE. Septum resists coring and is recommended for instruments with fine gauge needles. Also recommended for LC-MS and GC-MS due to high purity.

Septa Selection Guide - Thermo Fisher Scientific

PTFE/ High-performance red rubber septa -40 +110 -40 +230 PTFE/Silicone septa: (T/S) -60 +200 -76 +392 PTFE/Silicone/PTFE septa: (T/S/T)* -60 +200 -76 +392 PTFE septa* -200 +250 -328 +482 Butyl/Chlorobutyl/Bromobutyl stopper or septa -20 +125 -4 +257 Gray PTFE/Red rubber -40 +120 -40 +248 PTFE/White silicone purepack septa -60 +200 -76 +392

Step by Step Septa Tutorial Use Guide - Here’s How and Why

Mar 31, 2022 · PTFE/silicone septa. PTFE/Silicone is an ideal choice for analyzing volatile organic chemicals. These analyses happen at low concentrations or during operation at higher conditioning temperatures. Store PTFE/Silicone septa in a glass Purepak jar to ensure: 1. minimal background, 2. low permeability, 3. and the best performance of any headspace

Thermo Scientific 13mm Autosampler Vial Septa PTFE/Silicone

For use with 13-425 threaded caps or 13mm Snap/Crimp Caps, Thermo Scientific™ 13mm Septa are available in PTFE/ Red Rubber, PTFE/Silicone or Red PTFE/White Silicone/Red PTFE to suit a variety of applications. PTFE disk septa are chemically inert. PFTE/red rubber septa are economical for many GC applications.

Septa Selection Tool | Thermo Fisher Scientific - US

Silicone rubber septa. High quality, silicone rubber laminated to PTFE. Use when excellent resealing qualities are a must. Septum resists coring and is recommended when multiple injections are required. Preferred septa for use in liquid chromatography applications.

Vials | Fisher Scientific

Fisherbrand™ 11 mm Glass Wide Opening Crimp Top Vial Convenience Kits. Save time and reduce the risk of contamination by using Fisherbrand™'s vial convenience kits. Each kit includes 100 clear or amber glass vials and 100 crimp caps with pre-assembled septa. Height (Metric) 32 mm. Volume (Metric) Total. 2 mL.

Details of Aluminum Crimp Cap with PTFE/Silicone Septa for

Mar 25, 2022 · The crimp cap vial requires crimping tools to carry out the sealing process. ----The cap material is a metal aluminum cover. The design with a 9.5mm hole in the center of the cover can be used for

Complete Guide: 137 Pre-slit PTFE/Silicone Septa FAQs

Jun 12, 2023 · Comprehensive Guide to Syringe Filters: Features, Selection, Price, and Usage HPLC Vial Inserts: Enhancing Precision and Sample Integrity Premium PTFE and Silicone Septa: Reliable Sealing Solutions Wholesale COD-V50 16mm 100mm cod tube for water analysis V945 Cheap 2ml 9mm amber HPLC vials for sale V935 Wholesale 2ml amber HPLC vials from China V917 China 2ml 9mm chromatography vails factory