Silicone Rubber Septum: Key Considerations for Sample Containment and Analysis

Position:
Home » News » HPLC Septa Cap » Silicone Rubber Septum: Key Considerations for Sample Containment and Analysis

Tedlar® gas sampling bag septum, capacity, 1.6 L | Sigma-Aldrich

Reusable 2 mil thick bags made of Tedlar ® PVDF fluoropolymer film for sampling gases. Available with either a nickel-plated brass on/off valve that accepts 1 / 4 in. I.D. tubing or with a PTFE/silicone septum in a PP housing for use with a syringe needle. Applications include sampling: carbon monoxide, sulfur dioxide, hydrogen sulfide, radon

920969-00 Factors to Consider While Selecting Stoppers for

silicone is added to the stopper washer during the wash cycle (Reference 1). Caution must be taken so that the right amount of silicone oil is applied. Over siliconization may result in adverse reaction with the product producing a hazy appearance. Under siliconization may result in stoppers clumping together (Figure 3). Figure 3.

Thermal Decomposition and Ceramifying Process of Ceramifiable

May 15, 2019 · Ceramifiable silicone rubber composites have relatively lower heat-release rates and minimal sensitivity to external heat flux in comparison to most organic polymer composites [3,6,7]. Thermal decomposition of silicone rubber has been thoroughly studied, and good thermal resistance properties have also been demonstrated [8,9,10].

Headspace Vials & Headspace Caps - Aijiren

Headspace vials and caps are used in headspace gas chromatography analysis because of their ability to withstand the pressure from gas. Aijiren headspace vials come in two basic sizes (10 mL headspace vials and 20 mL headspace vials). Both flat bottom and round bottom styles are available for use in a wide variety of headspace instrument platforms.

An Aijiren Vial is Not Just a Vial

Figure 1 illustrates a complete sample containment solution of the vial, cap, and septum, and their relationship to each other. A needle is shown piercing the cap septum and, as shown in the fi gure, the septum should be the only component that comes into contact with the needle. Autosampler needle Septum Cap Vial Sample location F igure 1.

Rubber septums | Sigma-Aldrich - MilliporeSigma

Description. Pricing. Details. black polypropylene, septum (TEF/red rubber), septum thickness 1.3 mm, 8-425 thread. Expand. Hide. 854987. black polypropylene hole cap, thread for 13-425, PTFE/red rubber septum, for use with 4 mL vials with 13-425 thread, pkg of 100 ea. Expand.

Preparation and properties of silicone rubber materials with

Feb 1, 2021 · Figure 1 shows the preparation process for the foam/solid alternating multilayered silicone rubber foam materials. First, the samples in Table 1 are made into sheets with a thickness of 0.2 mm

Septa Selection Guide - Thermo Fisher Scientific

The silicone elastomer layer is dense but still easily pierced by most headspace sampling needles. Black rubber septa Black Rubber septa are molded from a higher density rubber compound compared to the standard red rubber. This septum has characteristics similar to the gray butyl stopper. The Black rubber septum is an economical choice for

Septum Selection Guide Rev 2 - Fisher Sci

PTFE/Silicone septum is provided with a thin 0.005” PTFE layer laminated to our high purity silicone and slit through the center to provide for easier needle penetration as well as to release the vacuum that forms when a large volume of sample is withdrawn from a vial.

Septa | Pawling Engineered Products

Products. Septa. By definition, a rubber septum consists of a disk of rubber or similar material used to seal a vial or other device. It is installed along the inside of a cap, which is typically made of metal or plastic. A syringe needle pierces the rubber septum for the purpose of injection and, on withdrawal, the elasticity of the septum

Step by Step Septa Tutorial Use Guide - Here’s How and Why

Mar 31, 2022 · 3. Pre-slit PTFE/red rubber . Red rubber that has been pre-slit and has a tiny (0.003″) PTFE coating. As mentioned before, this is ideal for undoing vial vacuuming or syringe needles with narrow gauges. Five types of silicone rubber. 1. PTFE/silicone – ST1, ST15, ST18, ST2 . The myriad of varieties of thickness makes PTFE/silicone ideal.

Septa | VWR

Septa. Septa are available in a variety of materials and thicknesses. PTFE Natural Rubber are moderately priced seals for GC and HPLC with good chemical properties. They are ideal for multiple injections due to high resealability, but not as easy to penetrate as PTFE/RR. PTFE/High Performance Rubber is a highly pure synthetic red rubber septum

NovaSeptum GO Sterile Sampling Systems - MilliporeSigma

minimizes the risk of both sample or process contamination. Our NovaSeptum® GO sterile sampling system is designed to meet the needs of sampling throughout aseptic and sterile processes. The innovative closed design isolates your sample from collection to analysis, maintaining sample integrity while reducing the possiblity of sample loss.

2 mL Snap Top Vials & 11 mm Snap Caps | Aijiren

The Aijiren snap top vials and caps range includes wide-opening snap top vials, 11 mm snap cap vials, and 11 mm snap caps. Aijiren snap top vials are made from high-quality clear or amber Type 1 borosilicate glass and are available with or without write-on spots for sample identification. Choose from a range of glass or plastic snap cap vials.

An Aijiren Septum is Not Just a Septum

Septa can be made from a range of materials including PTFE, silicone, red rubber, luoroelastomers, and butyl to name. few. The materials are layered together in one of three options: Choose a material that is as inert as possible to your sample analyte and makeup solvents.