Silicone septa for lab equipment in pharmaceutical analysis

Position:
Home » News » HPLC Septa Cap » Silicone septa for lab equipment in pharmaceutical analysis

How Pierced PTFE/Silicone Septa Affect GC-MS Experiments

Jan 2, 2006 · Figure 3 - Typical mass chromatogram of volatile residue in hexane caused by PTFE/silicone septa: a) hexane extract of a piece of septum; b) vial septum was punctured once by a syringe to sample 1 μL hexane for GC analysis; c) hexane in the last vial was reanalyzed after 3 days; and d) analyzed immediately after 100 μL hexane was added from one vial to another (the septum was punctured 10

Deactivated Clear Glass Vial | 12 x 32mm - Waters Corporation

Deactivated Clear Glass 12 x 32 mm Screw Neck Vial with Cap and Preslit PTFE/Silicone Septum, 2 mL Volume, 100/pk. When working with highly polar analytes that may associate with the polar glass surface, chromatographers choose deactivated vials as the effective vial of choice. These glass vials are treated with gas-phase, reactive organosilane

An Aijiren Septum is Not Just a Septum

Generally, silicone septa are more easily pierced than red rubber or butyl septa. For thicker, hard-to-pierce septa, a small gauge (23 gauge) needle may be required, or a stronger S-needle can be used. Preslit septa are the best option for easy penetration, reducing the likelihood of coring.

LCGC Certified Clear Glass Screw Neck Vial - Waters Corporation

To maintain cleanliness, each batch of lab equipment is examined independently. After the vials have been packaged for several days, this test is performed to confirm that any false positives or negatives have been eliminated. A headspace GC test is also performed to ensure that the silicone septa have adequately cured.

2-ml Vial Septa at Thomas Scientific

PerkinElmer. Screw Top Vials and 100 preassembled Black Caps with PTFE/Silicone Pre-slit Septa together in an environmentally clean, re-sealable clamshell pack. Volume: 2 mL Size: 12 x 32 mm I.D.: 10 mm Finish: Screw Top with Closure Kit Description: Amber glass vial PTFE/Silicone Pre-slit Septa with Black.

Septa selection guide

the solvent. PTFE/Silicone septa are ideal for use in most HPLC and GC applications where resealability and purity are critical. Pre-slit PTFE/silicone septa Pre-slit septa are offered in many of the same formulations as for non-slit PTFE/silicone septa and shares most of the physical and chemical characteristics. The septum is provided with a

Lab Equipment and Lab Supplies | Fisher Scientific

Shop Top Brands. Your source for innovative, indispensable lab equipment, lab supplies, and services. View our wide selection of products for scientific research and education.

Septa - MilliporeSigma

Septa. A wide range of serrated and non-serrated septa, and sleeve stoppers are available for use as temporary closures for glassware joints, tubes, bottles, NMR tubes, ampules, and cannulation techniques in air-sensitive chemistry. To protect your valuable contents in the vessels or containers from the atmosphere, our range of septa provide

Article 56: An In-Depth Guide: 137 Frequently - LinkedIn

Jul 11, 2023 · Yes, Pre-slit PTFE/Silicone Septas are commonly used in headspace analysis, which is a technique used for the analysis of volatile compounds in samples. The chemically inert nature of these septa

Stoppers | Fisher Scientific

Stoppers, also known as bungs, are used to give an airtight seal to laboratory flasks and test tubes by fitting tightly inside the neck of the container and preventing material from spilling. Stoppers can be made of glass, cork, rubber, or silicone. They are typically designed with a conical shape, but straight, flanged, and tapered options are

Septa Selection Tool | Thermo Fisher Scientific - US

Silicone rubber septa. High quality, silicone rubber laminated to PTFE. Use when excellent resealing qualities are a must. Septum resists coring and is recommended when multiple injections are required. Preferred septa for use in liquid chromatography applications.

20 Mm Crimp Caps at Thomas Scientific

Combine our quality vials with our Exclusive pressure relief caps/septa to ensure safe analysis at any temperature. Volume: 22 mL Size: 23 x 75.5 mm I.D.: 20 mm Finish: Crimp Top with Bevel Finish Bottom: Radius (or rounded) This vial is also available 100/pack (Part Number: N9306079) Compare this item.

Premium PTFE and Silicone Septa: Reliable Sealing Solutions

All About Vial Crimpers: A Detailed 13mm & 20mm Guide Comprehensive Guide to Syringe Filters: Features, Selection, Price, and Usage HPLC Vial Inserts: Enhancing Precision and Sample Integrity Premium PTFE and Silicone Septa: Reliable Sealing Solutions Wholesale COD-V50 16mm 100mm cod tube for water analysis V945 Cheap 2ml 9mm amber HPLC vials for sale V935 Wholesale 2ml amber HPLC vials from

Black Cap and Preslit PTFE/Silicone Septum for TruView Vials

SKU: 186005660CV. TruView pH Control LCMS Certified Clear Glass, 12 x 32 mm Screw Neck Vial, with Cap and PTFE/Silicone Septum , 2 mL Volume, 100/pk. This item is not available for sale. Contact Waters for more information. SKU: 186005826. Black Cap and PTFE/Silicone Septum for TruView Vials. This item is not available for sale.

Septa Selection Guide - Thermo Fisher Scientific

silicone/ PTFE Thin, fragile needle? Soft and thin septa required e.g. silicone/ PTFE Blunt, thick needle? Slit/pre- cut liner as penetration aid (HPLC) silicone/ PTFE, slit Critical analysis? Very clean liner required